Sleep tracking gets the clock right, not the deep sleep.
In a sleep lab, seven trackers caught at least 93% of sleep but only 18% to 54% of wake. What they measure well is when you sleep; deep sleep and REM are estimates.
Sleep tracking gives you two kinds of numbers on the same screen, and only one kind is measured. In 2021 Evan Chinoy and his team at the Naval Health Research Center in San Diego put seven consumer trackers next to polysomnography, the brain-wave recording a sleep lab uses as its reference (Chinoy et al., 2021). Thirty-four healthy adults aged 18 to 35 slept three nights in the lab, one of them broken up by a tone every hour, wearing watches and bands or sleeping next to bedside sensors. No device company paid for the study or had any say in it, which is rarer in this field than it should be.
How does a smartwatch know when you're asleep?
Mostly from movement, with heart rate or breathing added depending on the device. That works well for sleep itself: in the lab, every one of the seven devices caught at least 93% of the stretches polysomnography scored as sleep, but only 18% to 54% of the stretches it scored as wake (Chinoy et al., 2021). Lying awake and still counts as sleep to your watch.
If you lie in the dark trying to fall asleep, you barely move, so those minutes get counted as sleep (Lee et al., 2023). The two Garmin models found the least wake time (Chinoy et al., 2021). In 2022 Dean Miller and his team in Adelaide tested six newer devices, including Apple Watch, Oura and WHOOP, and saw the same pattern, with 90% to 98% of sleep found and 26% to 57% of wake (Miller et al., 2022).
Share of lab-scored stretches each tracker got right, seven devices. Sleep, weakest device: 93%; Wake, best device: 54%; Wake, weakest device: 18%.
Source: Chinoy et al., 2021
How accurate is a sleep tracker for total sleep time?
Often close on average, much less so on any single night. Across all nights the Fitbit Alta HR came in just 2.6 minutes above the lab, yet individual nights ranged from 42 minutes too little to 47 minutes too much (Chinoy et al., 2021). Both Garmin devices added 44 and 47 minutes of sleep on average. In Miller's study the Oura ring was 1.5 minutes off on average but up to 73.6 minutes either way on a given night (Miller et al., 2022). The error also grows on the nights you care about most: the Apple Watch, read out through the third-party app Sleep Watch, overestimated sleep by 10.1 minutes on good nights and by as much as 104.7 minutes on poor ones, and Chinoy's devices also did worse on disrupted nights (Chinoy et al., 2021).
Can a tracker tell you how much deep sleep you got?
Not reliably. On average, most devices in Chinoy's study missed 30% to 50% of deep sleep and REM sleep, and what they got wrong they mostly called light sleep (Chinoy et al., 2021). In Miller's study the stage matched the lab for only 50% to 65% of the night, and for 53% with the Apple Watch (Miller et al., 2022). A Korean study of 11 trackers in 75 adults with sleep complaints, including the Apple Watch 8, Fitbit Sense 2 and Oura Ring 3, found similarly modest agreement (Lee et al., 2023), though several of its authors hold shares in the company behind the top-ranked app. So a deep-sleep figure that jumps from night to night is mostly noise. The same caution applies to sounds sold for deep sleep: the 35.3 extra minutes in the best-known study of binaural beats for sleep were measured in a sleep lab, in 15 people on a single night. What actually changes deep sleep is covered in how to get more deep sleep.
| Number | In the lab | How to read it |
|---|---|---|
| Bedtime and wake time | valid for timing and duration (Miller et al., 2022) | as a range across the week |
| Total sleep | up to 73.6 minutes off per night (Miller et al., 2022) | weekly average, not one night |
| Wake during the night | only 18% to 54% detected (Chinoy et al., 2021) | probably too low |
| Deep and REM sleep | 30% to 50% missed (Chinoy et al., 2021) | do not compare night by night |
| Sleep score | tested in none of these studies (Chinoy et al., 2021; Lee et al., 2023; Miller et al., 2022) | as a trend at most |
A sleep score is a blend the maker does not publish, built from the numbers above, including the weak ones. None of the three validation studies here tested a score against the lab (Chinoy et al., 2021; Lee et al., 2023; Miller et al., 2022). If yours drops after a night you felt fine, the likeliest reason is the wake and stage estimates feeding it, not your sleep.
Orthosomnia: when the number makes sleep worse
In 2017 Kelly Glazer Baron and her team described three patients at a US sleep clinic who came in because of their tracker data, and gave the pattern a name, orthosomnia, the pursuit of correct sleep (Baron et al., 2017). All three were spending extra time in bed to push up the sleep their tracker reported, which may have made their insomnia worse. One patient, after a lab night that showed plenty of deep sleep, asked why her Fitbit said she was sleeping poorly. Three cases do not show that trackers cause sleep problems, and the team says plainly that it did not know how these patients slept before the tracker.
Two experiments show that the number alone can change your day. A British team led by Dimitri Gavriloff gave 63 people with insomnia made-up feedback after one night, half of it good and half bad (Gavriloff et al., 2018). Those told they had slept badly felt markedly less alert and more tired that evening, while a reaction-time test showed no difference. Christina Draganich and Kristi Erdal told 164 students that a new technique had measured 28.7% or 16.2% REM sleep, and the figure they heard predicted their score on an attention test while their own sense of how well they had slept did not (Draganich & Erdal, 2014). In the second experiment it held for two of four tests. If the numbers leave you sleeping worse than before, take the watch off for a week. If this lasts longer than four weeks, it belongs with a doctor, not in an article.
The one number worth reading in the morning
The clock times. Miller calls all six devices valid for the timing and duration of sleep, though not for its stages (Miller et al., 2022). Regularity of those times carries real information. Daniel Windred and his team analysed a week of wrist movement data from 60,977 UK Biobank participants, and over a little more than six years the most regular sleepers had a 20% to 48% lower risk of death than the least regular, with regularity predicting that risk better than sleep duration did (Windred et al., 2024). That is an observation, not proof, since the authors write that regularity may be both a cause and a marker of risk, and the device was a research sensor rather than a smartwatch. Still, the spread of your bedtimes is the one figure a watch measures well and you can change yourself, which the overview on a sleep schedule builds on.
- Every evening
Lights out at the same time, say 23:00, Fridays included
Regularity predicted more than sleep duration.
- 06:45
Look only at the time you fell asleep and woke up, skip stages and score
Stages matched the lab for 50% to 65% of the night.
- After a bad night
Get up at your usual time instead of catching up in bed
Extra time in bed may make insomnia worse.
- Sunday, 20:00
Write down the week's earliest and latest bedtime
Single nights scatter more than the average.
The same goes for numbers like HRV or resting heart rate: you read the trend over weeks, not last night, as the staying with it overview describes for any habit. The nine:thirty app reads your watch's sleep data from Apple Health and shows sleep duration and how steady your bedtime is next to the protocol, with no score of its own.
Tonight, set the time your light goes out, and on Sunday read only the range. Leave the stages to the watch.
Frequently asked questions
How accurate is sleep tracking?
Good at finding sleep, poor at finding wake. In a lab comparison of seven devices, each caught at least 93% of sleep but only 18% to 54% of wake (Chinoy et al., 2021). Total sleep was often close on average, but single nights could be off by more than an hour (Miller et al., 2022), and sleep stages were missed 30% to 50% of the time (Chinoy et al., 2021).
What is a good sleep score?
There is no lab standard for it. A sleep score is the maker's own blend of duration, wake and stage estimates, and none of the validation studies here tested a score against polysomnography (Chinoy et al., 2021; Lee et al., 2023; Miller et al., 2022). Read it as a trend over weeks at most, and trust your bedtime and wake time more than the number.
What is orthosomnia?
A term Kelly Glazer Baron and her team coined in 2017 for people who try to perfect their sleep-tracker data (Baron et al., 2017). So far it is described in three case reports, not in large studies. The typical pattern is spending longer in bed to raise the measured sleep time, even though that can make sleep worse.
Sources
- Baron, K. G., Abbott, S., Jao, N., Manalo, N., & Mullen, R. (2017). Orthosomnia: Are some patients taking the quantified self too far? Journal of Clinical Sleep Medicine, 13(2), 351–354. https://doi.org/10.5664/jcsm.6472
- Chinoy, E. D., Cuellar, J. A., Huwa, K. E., Jameson, J. T., Watson, C. H., Bessman, S. C., Hirsch, D. A., Cooper, A. D., Drummond, S. P. A., & Markwald, R. R. (2021). Performance of seven consumer sleep-tracking devices compared with polysomnography. Sleep, 44(5), Article zsaa291. https://doi.org/10.1093/sleep/zsaa291
- Draganich, C., & Erdal, K. (2014). Placebo sleep affects cognitive functioning. Journal of Experimental Psychology: Learning, Memory, and Cognition, 40(3), 857–864. https://doi.org/10.1037/a0035546
- Gavriloff, D., Sheaves, B., Juss, A., Espie, C. A., Miller, C. B., & Kyle, S. D. (2018). Sham sleep feedback delivered via actigraphy biases daytime symptom reports in people with insomnia: Implications for insomnia disorder and wearable devices. Journal of Sleep Research, 27(6), Article e12726. https://doi.org/10.1111/jsr.12726
- German Federal Statistical Office. (2021, February 22). 3.4 million people in Germany used smart health devices in 1st quarter of 2020 [Press release No. 078]. https://www.destatis.de/EN/Press/2021/02/PE21_078_639.html
- Lee, T., Cho, Y., Cha, K. S., Jung, J., Cho, J., Kim, H., Kim, D., Hong, J., Lee, D., Keum, M., Kushida, C. A., Yoon, I.-Y., & Kim, J.-W. (2023). Accuracy of 11 wearable, nearable, and airable consumer sleep trackers: Prospective multicenter validation study. JMIR mHealth and uHealth, 11, Article e50983. https://doi.org/10.2196/50983
- Miller, D. J., Sargent, C., & Roach, G. D. (2022). A validation of six wearable devices for estimating sleep, heart rate and heart rate variability in healthy adults. Sensors, 22(16), Article 6317. https://doi.org/10.3390/s22166317
- Windred, D. P., Burns, A. C., Lane, J. M., Saxena, R., Rutter, M. K., Cain, S. W., & Phillips, A. J. K. (2024). Sleep regularity is a stronger predictor of mortality risk than sleep duration: A prospective cohort study. Sleep, 47(1), Article zsad253. https://doi.org/10.1093/sleep/zsad253